    Integration Products > Enterprise Security Platform > RTIP
 

  RTIP-Real-Time
              Interface Processor

Print This Page
 
 


Description

RTIP - Real-Time Interface Processor is used to service multiple remote processors, including Real-Time Network Processors (RTNP’s) , Real-Time Access Control Processors (RTAP’s), Real-Time Monitoring Processors (RTMP’s) and WSA Fire Alarm Control Panels Series 3000, Series 1000 and Series 2000, as well as communicate with the ESP Server ( WGY Host) via Local Network (or a dial-up phone line). (RTPI™).

The communication between the Real-Time Processors, Fire Alarm Controls Panels, and WGY Host through the RTIP is transparent.

RTIP uses any of a number of protocols including ModBus, BACnet, Real-Time Privacy Infrastructure (RTPI™), etc. The RTPI™ is a patent pending security technology/protocol developed by WeGuardYou which utilizes scalable and random encryption methods. This modulated encryption establishes a secure communication channel impervious to external attacks.

The distributed intelligent Real-Time Interface Processors (RTIP’s) are based on microprocessor technology, and provides completely autonomous operation as a result of their inherent intelligence and stored operating data.

RTIP’s firmware is programmed in a high-level language for ease of maintenance and enhancement. All RTIP operational code is stored in non-volatile Flash memory while monitoring data and system parameters are stored in battery backed-up RAM. Each RTIP contains an on-board real-time, battery backed-up clock for communication control, event initiation, and date/time stamping of transactions.

The RTIP is capable of dialing up to four different telephone numbers in a pre-determined order. Communication parameters such as communication speed, parity, and stop bits, number of retries and interval between retries are configurable.

Technical Specifications

Ambient Temperature ......................................................................32°F to 120°F (0°C to 49°C)
Humidity ...........................................................................................0 to 90% Non-condensing
Material .............................................................................................16 gauge steel enclosure
Finish .....................................................................................................Textured black epoxy
Dimensions ...................................................................5”H x 6”W x 1”D (12.7 x 15.2 x 2.5 cm)
Mounting ................................................................Surface – 4 holes provided (2 keyhole slots)
Weight (maximum net) .................................................................................................0.5 lbs.
Power Requirements ....................................................................................................12VDC
Speed ..........................................................................................................300 to 19200 bps
Firmware ..............................................................................Flash, Removable and Upgradable

Communications

ModBus ...........................RTU or ASCII protocols, Master or Slave, RS232/485 or TCP/IP

BACnet

Driver Type .........................................................................BACnet IP, (Annex J)

                           ..................................ANSI/ATA 878.1, 2.5 Mbps, ARCNET (Clause 8)
                           ..................................ANSI/ATA 878.1, 2.5 Mbps, ARCNET (Clause 8)
                           ..................................ANSI/ATA 878.1, 2.5 Mbps, ARCNET (Clause 8)
                           ..................................ANSI/ATA 878.1, 2.5 Mbps, ARCNET (Clause 8)
                           ..................................ANSI/ATA 878.1, 2.5 Mbps, ARCNET (Clause 8)

Connection ........................................................................BACnet/PTP: RS-232

                            .........BACnet/MSTP: Master-Slave/Token-Passing, Multi-drop, RS-485
                            ......................................................BACnet/ARCnet: ATA/ANSI 878.1
                            ..............BACnet/IP: Internet Protocol (IP), 10BaseT, BBMD supported
                            .............................................BACnet/Ethernet: ISO 8802.3, 10BaseT
 

RTPI (Real-Time Privacy Infrastructure) ........................................RS232, RS485, TCP/IP

                                ..................................Real-Time Access Control Processor (RTAP)
                                .......................................  Real-Time Monitoring Processor (RTMP)
                                ............................................ Real-Time Network Processor (RTNP)
                                .......... WSA Series 3000 and Series 1000 Fire Alarm Control Panels
                                ................... WeGuardYou Enterprise Security Platform (WGY-ESP)